Schneider Electric A9F05204 — 2-Pole MCB (DIN Rail)

Schneider A9F05204 Acti9 iC60N MCB, 4 A D-curve, 2P

MPNA9F05204
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F05204, 4 A, D-curve, 2-pole, 50 kA breaking capacity at 415 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05204 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F05204 — Electrical
ParameterValue
Rated current [In]4 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F05204 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F05204 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F05204 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F05204 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

What this MCB does on the line

Two poles, thermal-magnetic trip, rated 4 A continuous. The D-curve magnetic trip fires at 12 x In (±20 %), so a 4 A breaker holds through 48 A inrush peaks without nuisance tripping. Breaking capacity: 50 kA Icu at 415 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V (EN/IEC 60898-1). The dual standard means it qualifies for both industrial distribution panels (60947-2) and final sub-circuits (60898-1) — one part covers both, which simplifies BOM management.

Width is 36 mm (4 x 9 mm pitches), depth 78.5 mm, height 91 mm. That 36 mm footprint for a 2-pole breaker is standard — no surprises when laying out a multi-way distribution board. Tightening torque 2 N·m. Wire strip length 14 mm. IP20 finger-safe terminals — fine for enclosed panels; not rated for wet environments.

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household/residential). Isolation-capable per both standards. Limitation class 3. Suitability for isolation marked on the device.

Frequently asked questions

Where can I buy the A9F05204 and get current pricing?

The A9F05204 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the A9F05204 at 415 V?

50 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

What does the D-curve mean on this 4 A breaker?

The D-curve trips magnetically at 12 x In (48 A for this 4 A unit), so it holds through motor-start and transformer inrush without nuisance tripping.

What compliance documentation does Schneider provide for the A9F05204?

The breaker carries dual certification to EN/IEC 60947-2 and EN/IEC 60898-1, with isolation suitability marked per both standards. Pollution degree 3, overvoltage category IV, tropicalisation class 2.