Schneider Electric A9F05406

Schneider Electric A9F05406 Acti9 iC60N MCB, D Curve, 6 A, 4

MPN A9F05406
Obsolete

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F05406, D curve, 6 A rated current, 4 poles, breaking capacity 36 kA at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05406 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05406 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05406 is an Acti9 iC60N miniature circuit breaker (MCB) with a D tripping curve, rated 6 A across 4 protected poles. The D curve's magnetic trip threshold of 12 x In ±20 % means it tolerates short-duration surges up to roughly 72 A before the solenoid fires, while still clearing a hard fault within the rated breaking capacity. This is a thermal-magnetic breaker, so the bimetal strip handles sustained overloads (the 6 A continuous rating) and the magnetic coil handles short-circuits. It is dual-rated to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic / commercial), which is the standard split for a part that might sit in a panel feeding a motor starter or a distribution board feeding lighting and sockets. The utilisation category is A per EN/IEC 60947-2, meaning it is not intended for frequent switching of loads — it is a protection device, not a switch.

The A9F05406 carries a breaking capacity that varies by voltage, which is typical for an MCB rated under both standards. At 12-133 V AC it can interrupt 36 kA (Icu per EN/IEC 60947-2); at 220-240 V AC that drops to 20 kA; at 380-415 V AC it is 10 kA; and at 440 V AC it is 6 kA. The limitation class is 3 per EN/IEC 60898-1, which means it lets through less energy than a class 1 or 2 device — important for downstream equipment protection and for coordinating with a downstream sub-distribution board. For a panel OEM or site engineer, the relevant figure is the one at your system voltage. If your supply transformer can deliver 25 kA at 240 V, this breaker covers it. If you are on a 400 V industrial bus with a prospective fault current of 15 kA, the 10 kA rating at 380-415 V is the limit — you would need a higher-rated device or a current-limiting upstream fuse. The overvoltage category is IV, so it is rated for the main distribution board, not just a sub-panel.

The 4-pole body takes 8 x 9 mm pitches of rail space — 72 mm wide. Depth is 78.5 mm, height 91 mm. IP20 rated, so it is for inside an enclosure, not for wet locations. The toggle is the control type, and there is a trip indicator for local signalling — useful when you are walking a panel and want to see which breaker tripped without metering.

MPN
A9F05406