A9F05410 Acti9 iC60N MCB, 10 A, Curve D, 4P, 36 kA

MPN A9F05410
Active

Schneider Electric Acti9 iC60N, A9F05410, miniature circuit-breaker, 4P, 10 A, D-curve, 36 kA Icu at 133 V AC, thermal-magnetic, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05410 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05410 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F05410 is a 4-pole (4P) miniature circuit-breaker from the Acti9 iC60N series, rated 10 A with a D-curve — magnetic trip at 12 x In (±20 %), so it handles inrush from motor loads, transformers, or welding equipment without nuisance tripping on startup. The thermal-magnetic trip unit covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one package. Breaking capacity hits 36 kA Icu at 12–133 V AC (EN/IEC 60947-2), enough for high-fault panels near substations; derates to 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V. Under EN/IEC 60898-1 it's rated 10 kA Icn at 400 V — the standard for domestic/commercial distribution boards. That dual-standard certification (60947-2 for industrial, 60898-1 for distribution) means it qualifies for either a control-panel feeder or a sub-distribution board.