Schneider Electric A9F05413

Schneider Electric A9F05413 Acti9 iC60N MCB, D Curve, 13 A,

MPN A9F05413
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, 13 A, D curve, 4P, 36 kA breaking capacity at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05413 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F05413 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05413 is an Acti9 iC60N miniature circuit breaker rated 13 A with a D tripping curve, 4 poles, and a thermal-magnetic trip unit. It's built for distribution panels where high inrush loads — motor starts, transformer energization, or capacitive banks — demand the D curve's 12 x In magnetic trip threshold. The 36 kA Icu at 12-133 V AC (per IEC 60947-2) gives real fault-clearing headroom on low-voltage secondaries; at 400 V it still holds 10 kA Icu, enough for most European industrial panels.

The D curve (12 x In +/- 20%) means this breaker holds through short-duration current spikes up to roughly 156 A before the magnetic trip fires. The 13 A rating is the continuous thermal current; wire the load at 13 A or below, sized per the terminal range (1-25 mm² rigid, 1-16 mm² flexible). Breaking capacity is dual-rated: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V (all per IEC 60947-2). Under IEC 60898-1 it's rated 10 kA Icn at 400 V. The 36 kA figure at low voltage is useful for high-fault locations near transformers; the 6 kA at 440 V still covers standard distribution. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/commercial), so it qualifies for both IEC 61439 switchgear assemblies and domestic consumer units.

Snaps onto standard DIN rail. 72 mm wide (8 x 9 mm pitches), 91 mm tall, 78.5 mm deep. The toggle actuator and trip indicator give local status at a glance. IP20 finger-safe terminals for enclosed panel use.