Skip to main content
Schneider Electric A9F05413 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F05413 Acti9 iC60N MCB, D Curve, 13 A,

MPNA9F05413
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, 13 A, D curve, 4P, 36 kA breaking capacity at 12-133 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05413 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F05413 — Ratings
ParameterValue
Rated current (In)13 A
Poles configuration4P
Number of protected poles4
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F05413 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F05413 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F05413 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F05413 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05413 is an Acti9 iC60N miniature circuit breaker rated 13 A with a D tripping curve, 4 poles, and a thermal-magnetic trip unit. It's built for distribution panels where high inrush loads — motor starts, transformer energization, or capacitive banks — demand the D curve's 12 x In magnetic trip threshold. The 36 kA Icu at 12-133 V AC (per IEC 60947-2) gives real fault-clearing headroom on low-voltage secondaries; at 400 V it still holds 10 kA Icu, enough for most European industrial panels.

The D curve (12 x In +/- 20%) means this breaker holds through short-duration current spikes up to roughly 156 A before the magnetic trip fires. The 13 A rating is the continuous thermal current; wire the load at 13 A or below, sized per the terminal range (1-25 mm² rigid, 1-16 mm² flexible). Breaking capacity is dual-rated: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V (all per IEC 60947-2). Under IEC 60898-1 it's rated 10 kA Icn at 400 V. The 36 kA figure at low voltage is useful for high-fault locations near transformers; the 6 kA at 440 V still covers standard distribution. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/commercial), so it qualifies for both IEC 61439 switchgear assemblies and domestic consumer units.

Snaps onto standard DIN rail. 72 mm wide (8 x 9 mm pitches), 91 mm tall, 78.5 mm deep. The toggle actuator and trip indicator give local status at a glance. IP20 finger-safe terminals for enclosed panel use.

Frequently asked questions

What is the breaking capacity of A9F05413 at 400 V?

At 380-415 V AC it's rated 10 kA Icu per IEC 60947-2, and at 400 V AC it's rated 10 kA Icn per IEC 60898-1.

What does the D curve mean on this breaker?

The D curve trips magnetically at 12 x In (156 A for the 13 A version), making it suitable for circuits with high inrush currents like motor starters, transformers, or discharge lighting.

Where can I buy the A9F05413?

We source this active-production part to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time.

MPN