Skip to main content
Schneider Electric A9F06125

Schneider Electric A9F06125 Acti9 iC60H MCB, 25 A, B-Curve,

MPN A9F06125
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 25 A, B-curve, 1-pole, 42 kA breaking capacity at 12-60 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06125 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06125 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06125 is a Schneider Electric Acti9 iC60H miniature circuit breaker rated 25 A with a B-curve trip characteristic, single-pole, for distribution panels on DIN rail. Breaking capacity hits 42 kA Icu at 12–60 V AC, giving headroom for high-fault panels without cascading upstream.

This iC60H carries a 42 kA Icu at 12–60 V AC — that's the maximum fault current it can interrupt without welding contacts or rupturing the case. At 220–240 V AC the rating drops to 15 kA Icu, still enough for most commercial distribution boards. The dual standard listing (EN/IEC 60947-2 and EN/IEC 60898-1) means it's certified for both industrial and household-style installations; the 60947-2 rating governs the SCCR you'd use in a UL 508A panel.

Mounts on standard DIN rail, occupies 2 x 9 mm pitches — 18 mm wide. Depth is 78.5 mm, height 91 mm. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible; torque to 2 N·m. The trip indicator and contact position indicator give a quick visual on faulted circuits without opening the panel door.

MPN
A9F06125