Schneider Electric A9F06125 — 1-Pole MCB (DIN Rail)

Schneider Electric A9F06125 Acti9 iC60H MCB, 25 A, B-Curve,

MPNA9F06125
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 25 A, B-curve, 1-pole, 42 kA breaking capacity at 12-60 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06125 — Identification
ParameterValue
Product nameActi9 iC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiC60H
Poles description1P
Number of protected poles1
Device applicationDistribution

Electrical & Protection

A9F06125 — Electrical & Protection
ParameterValue
Rated current (In)25 A
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu / AIR)42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles

Mounting & Connection

A9F06125 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Width18 mm
Height91 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom

Environmental

A9F06125 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529

Approvals

A9F06125 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1

Electrical

A9F06125 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

The A9F06125 is a Schneider Electric Acti9 iC60H miniature circuit breaker rated 25 A with a B-curve trip characteristic, single-pole, for distribution panels on DIN rail. Breaking capacity hits 42 kA Icu at 12–60 V AC, giving headroom for high-fault panels without cascading upstream.

This iC60H carries a 42 kA Icu at 12–60 V AC — that's the maximum fault current it can interrupt without welding contacts or rupturing the case. At 220–240 V AC the rating drops to 15 kA Icu, still enough for most commercial distribution boards. The dual standard listing (EN/IEC 60947-2 and EN/IEC 60898-1) means it's certified for both industrial and household-style installations; the 60947-2 rating governs the SCCR you'd use in a UL 508A panel.

Mounts on standard DIN rail, occupies 2 x 9 mm pitches — 18 mm wide. Depth is 78.5 mm, height 91 mm. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible; torque to 2 N·m. The trip indicator and contact position indicator give a quick visual on faulted circuits without opening the panel door.

Frequently asked questions

Who supplies A9F06125 and how is it quoted for volume purchases?

The A9F06125 is supplied through independent industrial-automation distributors. Volume pricing and lead time are confirmed at quote time against an RFQ — no public price list applies.

What is A9F06125's listed depth (78.5 mm) on this component line?

The A9F06125 has a depth of 78.5 mm, which fits standard DIN-rail enclosures with at least 90 mm internal depth.

What is A9F06125's listed range (Acti9) on this component line?

The A9F06125 belongs to the Schneider Electric Acti9 range, specifically the iC60H series — a compact miniature circuit breaker family for distribution applications.

What compliance documentation does this brand provide for A9F06125 (RoHS, REACH, UL, IEC)?

The A9F06125 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries a suitability-for-isolation mark per both standards. RoHS/REACH declarations are typically available from Schneider Electric's documentation portal for the Acti9 iC60H series.

MPN