A9F06232 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06232 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06232 is a 2-pole Acti9 iC60H miniature circuit-breaker rated 32 A with a B tripping curve — magnetic trip at 4 x In (±20 %). That curve B means it clears short-circuit currents fast enough to protect resistive or low-inrush loads like lighting circuits or control transformers, but it's not the right choice for motor starters where a C or D curve handles the inrush without nuisance trips. Breaking capacity hits 42 kA Icu at 133 V AC and 30 kA at 240 V AC, so it shrugs off high fault currents right at the distribution board without welding contacts shut.

Snaps onto a DIN rail — 36 mm wide (4 x 9 mm pitches), 91 mm tall, 78.5 mm deep. Double terminals top and bottom accept 1…35 mm² rigid or 1…25 mm² flexible, with a tightening torque of 3.5 N.m. Strip length is 14 mm — mark it on the wire before you crimp; too short and the conductor won't seat under the clamp.