Schneider Electric A9F06232 — 2-Pole MCB (DIN Rail)

A9F06232 Acti9 iC60H MCB, 2P, 32 A, Curve B, 42 kA

MPNA9F06232
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F06232, 2P, 32 A rated, curve B, breaking capacity 42 kA Icu at 133 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F06232 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F06232 — Electrical
ParameterValue
Rated current [In]32 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F06232 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F06232 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F06232 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F06232 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06232 is a 2-pole Acti9 iC60H miniature circuit-breaker rated 32 A with a B tripping curve — magnetic trip at 4 x In (±20 %). That curve B means it clears short-circuit currents fast enough to protect resistive or low-inrush loads like lighting circuits or control transformers, but it's not the right choice for motor starters where a C or D curve handles the inrush without nuisance trips. Breaking capacity hits 42 kA Icu at 133 V AC and 30 kA at 240 V AC, so it shrugs off high fault currents right at the distribution board without welding contacts shut.

Snaps onto a DIN rail — 36 mm wide (4 x 9 mm pitches), 91 mm tall, 78.5 mm deep. Double terminals top and bottom accept 1…35 mm² rigid or 1…25 mm² flexible, with a tightening torque of 3.5 N.m. Strip length is 14 mm — mark it on the wire before you crimp; too short and the conductor won't seat under the clamp.

Frequently asked questions

Where can I buy A9F06232?

The A9F06232 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9F06232's breaking capacity?

The A9F06232 has a breaking capacity of 42 kA Icu at 12…133 V AC, 30 kA at 220…240 V AC, 15 kA at 380…415 V AC, and 10 kA at 440 V AC per EN/IEC 60947-2. It also carries a 10 kA Icn at 400 V AC per EN/IEC 60898-1.

What standards does A9F06232 comply with?

It complies with EN/IEC 60947-2 and EN/IEC 60898-1. It is also suitable for isolation per both standards.