Schneider Electric A9F06320 Acti9 iC60H MCB, 20 A, B-Curve,

MPN A9F06320
Active

Schneider Electric Acti9 iC60H, A9F06320, miniature circuit breaker, 20 A, B-curve, 3P, 42 kA Icu at 12-133 V AC, DIN-rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06320 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06320 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06320 is a 20 A, B-curve, 3-pole miniature circuit breaker from the Schneider Electric Acti9 iC60H series. Its 42 kA Icu at 12-133 V AC (per EN/IEC 60947-2) is the highest short-circuit rating on this voltage range — meaning it safely interrupts faults up to that level without upstream cascading in a 400 V distribution panel. The B-curve magnetic trip at 4 x In ±20 % (80 A nominal) is sized for resistive and general-purpose loads where inrush is low; it will nuisance-trip on motor or transformer starts, so verify the load type before committing the BOM line. Dual-rated to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar), this breaker qualifies for panel-building under either standard. The 20 A rating is the continuous current at 50/60 Hz; the thermal-magnetic trip unit handles overloads and short-circuits in one package.

The 3-pole body occupies 6 x 9 mm pitches (54 mm width), with a depth of 78.5 mm and height of 91 mm. IP20 finger-safe terminals accept double connections: 1-25 mm² rigid or 1-16 mm² flexible, top or bottom. The toggle control and trip indicator give local status without opening the panel door.