Skip to main content
Schneider Electric A9F06320 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F06320 Acti9 iC60H MCB, 20 A, B-Curve,

MPNA9F06320
Active

Schneider Electric Acti9 iC60H, A9F06320, miniature circuit breaker, 20 A, B-curve, 3P, 42 kA Icu at 12-133 V AC, DIN-rail mount, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06320 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06320 — Ratings
ParameterValue
Rated current (In)20 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06320 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06320 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F06320 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06320 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06320 is a 20 A, B-curve, 3-pole miniature circuit breaker from the Schneider Electric Acti9 iC60H series. Its 42 kA Icu at 12-133 V AC (per EN/IEC 60947-2) is the highest short-circuit rating on this voltage range — meaning it safely interrupts faults up to that level without upstream cascading in a 400 V distribution panel. The B-curve magnetic trip at 4 x In ±20 % (80 A nominal) is sized for resistive and general-purpose loads where inrush is low; it will nuisance-trip on motor or transformer starts, so verify the load type before committing the BOM line. Dual-rated to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar), this breaker qualifies for panel-building under either standard. The 20 A rating is the continuous current at 50/60 Hz; the thermal-magnetic trip unit handles overloads and short-circuits in one package.

The 3-pole body occupies 6 x 9 mm pitches (54 mm width), with a depth of 78.5 mm and height of 91 mm. IP20 finger-safe terminals accept double connections: 1-25 mm² rigid or 1-16 mm² flexible, top or bottom. The toggle control and trip indicator give local status without opening the panel door.

Frequently asked questions

What is the breaking capacity of A9F06320?

The A9F06320 carries a 42 kA Icu at 12-133 V AC, 30 kA Icu at 220-240 V AC, 15 kA Icu at 380-415 V AC, and 10 kA Icu at 440 V AC, all per EN/IEC 60947-2. Under EN/IEC 60898-1 it is rated 15 kA Icn at 400 V AC.

How do I get current pricing and availability for A9F06320?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability at the time of order.

What compliance documentation does Schneider provide for A9F06320?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries IP20 protection per IEC 60529 and tropicalisation class 2 per IEC 60068-1. The manufacturer provides the standard declaration of conformity and test reports for these standards.

MPN
A9F06320