Skip to main content
Schneider Electric A9F06406

A9F06406 Acti9 iC60H MCB, 6 A B-curve 4P, 42 kA breaking cap

MPN A9F06406
Active

Schneider Electric Acti9 iC60H, A9F06406, miniature circuit breaker, 4P, 6 A, B-curve, 42 kA Icu at 133 V AC, dual-rated EN/IEC 60947-2 and 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06406 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06406 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06406 is a Schneider Electric Acti9 iC60H miniature circuit breaker: 4 poles, 6 A rated current, B-curve trip characteristic. The B-curve trips magnetically at 4 x In (±20 %), meaning it clears short-circuit faults quickly on resistive or lighting loads where inrush is low — a good fit for control transformers, small power supplies, or general-purpose branch circuits where you want selectivity upstream of a C-curve breaker. Breaking capacity is the headline number here: 42 kA Icu at 12…133 V AC, 30 kA at 220…240 V, 15 kA at 380…415 V, and 10 kA at 440 V (all per EN/IEC 60947-2). Under the 60898-1 standard it carries 10 kA Icn at 400 V. For a 6 A frame that is serious fault-clearing headroom — you can install this near a large transformer or in a high-fault panel without worrying about cascading failure upstream.

The 4-pole body takes 8 x 9 mm pitches — 72 mm wide — so it occupies four module spaces in a distribution board. Height is 91 mm, depth 78.5 mm. Terminals accept double conductors: 1…25 mm² rigid or 1…16 mm² flexible, with a strip length of 14 mm and a tightening torque of 2 N.m. The toggle handle provides local on/off control and a trip indicator shows when the breaker has opened on fault. IP20 rated — suitable for installation inside an enclosed panel only.

MPN
A9F06406