Schneider Electric A9F06406 — Miniature Circuit Breakers (MCB)

A9F06406 Acti9 iC60H MCB, 6 A B-curve 4P, 42 kA breaking cap

MPNA9F06406
Active

Schneider Electric Acti9 iC60H, A9F06406, miniature circuit breaker, 4P, 6 A, B-curve, 42 kA Icu at 133 V AC, dual-rated EN/IEC 60947-2 and 60898-1.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06406 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06406 — Ratings
ParameterValue
Rated current (In)6 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06406 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06406 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F06406 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06406 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06406 is a Schneider Electric Acti9 iC60H miniature circuit breaker: 4 poles, 6 A rated current, B-curve trip characteristic. The B-curve trips magnetically at 4 x In (±20 %), meaning it clears short-circuit faults quickly on resistive or lighting loads where inrush is low — a good fit for control transformers, small power supplies, or general-purpose branch circuits where you want selectivity upstream of a C-curve breaker. Breaking capacity is the headline number here: 42 kA Icu at 12…133 V AC, 30 kA at 220…240 V, 15 kA at 380…415 V, and 10 kA at 440 V (all per EN/IEC 60947-2). Under the 60898-1 standard it carries 10 kA Icn at 400 V. For a 6 A frame that is serious fault-clearing headroom — you can install this near a large transformer or in a high-fault panel without worrying about cascading failure upstream.

The 4-pole body takes 8 x 9 mm pitches — 72 mm wide — so it occupies four module spaces in a distribution board. Height is 91 mm, depth 78.5 mm. Terminals accept double conductors: 1…25 mm² rigid or 1…16 mm² flexible, with a strip length of 14 mm and a tightening torque of 2 N.m. The toggle handle provides local on/off control and a trip indicator shows when the breaker has opened on fault. IP20 rated — suitable for installation inside an enclosed panel only.

Frequently asked questions

Where can I buy A9F06406 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is A9F06406's listed depth?

The listed depth is 78.5 mm, which fits within the standard 80 mm deep distribution board cut-out.

What compliance documentation does this brand provide for A9F06406?

The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. It carries suitability for isolation marking per both standards. RoHS and REACH compliance documentation is standard for the Acti9 range, though specific declaration documents should be requested at quote time.

What is the closest alternative to A9F06406 in the same family?

Within the Acti9 iC60 range, the closest sibling is a C-curve variant at the same 6 A / 4P rating — the C-curve trips magnetically at 7-10 x In instead of 4 x In, so it handles higher inrush (motor or transformer loads) without nuisance tripping. The B-curve is preferred for resistive or electronic loads where short-circuit protection speed is the priority.