Skip to main content
Schneider Electric A9F07170

Schneider Electric A9F07170 Acti9 iC60H MCB, 0.5 A, 1P, C Cu

MPN A9F07170
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 1P, 0.5 A, C curve, 70 kA Icu at 240 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07170 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07170 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F07170 is a 1-pole Acti9 iC60H miniature circuit breaker rated at 0.5 A with a C curve (magnetic trip at 8 x In ±20 %). The 70 kA Icu breaking capacity at 240 V AC (per EN/IEC 60947-2) is its real fault-interruption muscle — it can safely interrupt a 70,000 A prospective fault without welding contacts or exploding the case. That rating matters if this breaker sits downstream of a large transformer or in a high-fault-capacity panel; the 10,000 A Icn per EN/IEC 60898-1 is the domestic-standard rating for the same part. Overvoltage category IV and pollution degree 3 mean the breaker is designed for the main distribution board at the service entrance, not just sub-panels. It tolerates the transient overvoltages and conductive dust typical of industrial switchboards. Dual certification to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic) gives it a broader application scope than an MCB carrying only one standard.

Deployment and integration

At 18 mm wide (2 x 9 mm pitches), it occupies one modular space in a distribution board. The double terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip length is 14 mm, tighten to 2 N·m. The toggle handle and trip indicator give local visual status. IP20 finger-safe terminals suit enclosed panels — not for wet or washdown environments.

MPN
A9F07170