Skip to main content
Schneider Electric A9F07302

Schneider Electric A9F07302 Acti9 iC60H MCB, 3P C-Curve 2A,

MPN A9F07302
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 3P, C-curve, 2 A, 70 kA Icu, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07302 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07302 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07302 is a 3-pole Acti9 iC60H miniature circuit breaker with a C-curve, rated at 2 A. It is a thermal-magnetic trip unit designed for distribution applications in AC or DC networks.

This breaker carries a 70 kA Icu at 220...240 V AC and at 380...415 V AC per EN/IEC 60947-2. At 440 V AC the Icu drops to 50 kA, and under the EN/IEC 60898-1 standard its Icn (rated short-circuit capacity) is 10 kA at 400 V AC. The Icn of 10 kA is the value used for domestic/similar installations. It is also rated for isolation — you can use it as a disconnecting means, verified by the contact position indicator that shows when the contacts are open.

Mounting and integration — DIN rail fit

The 3-pole body takes 6 x 9 mm pitches, so the occupied width is 54 mm. Depth is 78.5 mm, height 91 mm. IP20 finger-safe terminals — fine inside a closed panel, not for wet locations. The white colour is standard for the Acti9 range.

Lifecycle stage is current — this is an active, in-production part from Schneider Electric's Acti9 family. Pollution degree 3 means it is rated for the conductive environment inside a typical industrial panel. Overvoltage category IV confirms it can be used at the service entrance or main distribution board. Earth-leakage protection is a separate block — this MCB alone does not provide GFCI; pair it with a Vigic iC60 if needed.

MPN