Skip to main content
Schneider Electric A9F07313

Schneider Electric A9F07313 Acti9 iC60H MCB, 13 A, 3P, C Cur

MPN A9F07313
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 13 A, 3P, C curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07313 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F07313 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07313 is an Acti9 iC60H miniature circuit-breaker rated 13 A, 3 poles, C curve. It carries a 42 kA Icu breaking capacity at 12–133 V AC and 30 kA at 220–240 V AC, certified to both EN/IEC 60947-2 and EN/IEC 60898-1. That dual-standard rating means it can serve as a distribution board MCB under 60898-1 or as an industrial circuit breaker under 60947-2, giving you flexibility in panel design.

Breaking capacity and curve

The C curve magnetic trip is set at 8 x In ±20 %, so it holds through motor inrush and transformer energisation without nuisance tripping — typical for mixed resistive-inductive loads in distribution panels. The 42 kA Icu at low voltage (12–133 V AC) is unusually high for a 13 A frame; it handles high-fault-current scenarios like large UPS output or DC-link protection. At 400 V AC the Icn under 60898-1 is 10 kA, matching standard domestic-commercial board requirements.

Mounts on DIN rail, 6 modules wide (54 mm). Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible, with a 2 N.m tightening torque and 14 mm strip length. The IP20 finger-safe terminals are standard for enclosed panels.

MPN
A9F07313