Skip to main content
Schneider Electric A9F07413

Schneider Electric A9F07413 Acti9 iC60H MCB, 4P C-curve 13 A

MPN A9F07413
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07413, 4 poles, C-curve, 13 A rated current, 42 kA Icu breaking capacity at 133 V AC, dual-standard EN/IEC 60947-2 and EN/IEC 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07413 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F07413 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07413 is a 4-pole miniature circuit-breaker from the Acti9 iC60H series, rated 13 A with a C-curve trip characteristic. It is dual-rated to both EN/IEC 60947-2 and EN/IEC 60898-1, meaning it carries the higher breaking capacity of an industrial breaker (42 kA Icu at 12...133 V AC) while also meeting the residential/commercial MCB standard. That dual rating is the key spec for a buyer: it lets you use this one part number for distribution panels where you need the SCCR headroom of a 60947-2 device, not just a 60898-1 domestic MCB.

The 42 kA Icu at 133 V AC is the headline figure, but the real-world selectivity picture depends on the voltage on your bus. At 220...240 V AC the Icu drops to 30 kA; at 380...415 V AC it's 15 kA; at 440 V AC it's 10 kA. Under the 60898-1 standard the Icn is 15 kA at 400 V AC. For a 400 V distribution panel, the 15 kA Icu at 415 V is what governs your upstream breaker coordination — that's the figure to plug into your selectivity study, not the 42 kA number.

Height is 91 mm, depth 78.5 mm. The double terminal accepts 1...25 mm² rigid or 1...16 mm² flexible wire; strip length 14 mm, tighten to 2 N.m. IP20 finger-safe front, pollution degree 3 rated, overvoltage category IV. That's a standard panel footprint — no surprises for a panel builder laying out a 4-pole MCB in a distribution board.

MPN
A9F07413