Skip to main content
Schneider Electric A9F07413 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F07413 Acti9 iC60H MCB, 4P C-curve 13 A

MPNA9F07413
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07413, 4 poles, C-curve, 13 A rated current, 42 kA Icu breaking capacity at 133 V AC, dual-standard EN/IEC 60947-2 and EN/IEC 60898-1.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07413 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F07413 — Ratings
ParameterValue
Rated current (In)13 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F07413 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07413 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F07413 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F07413 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F07413 is a 4-pole miniature circuit-breaker from the Acti9 iC60H series, rated 13 A with a C-curve trip characteristic. It is dual-rated to both EN/IEC 60947-2 and EN/IEC 60898-1, meaning it carries the higher breaking capacity of an industrial breaker (42 kA Icu at 12...133 V AC) while also meeting the residential/commercial MCB standard. That dual rating is the key spec for a buyer: it lets you use this one part number for distribution panels where you need the SCCR headroom of a 60947-2 device, not just a 60898-1 domestic MCB.

The 42 kA Icu at 133 V AC is the headline figure, but the real-world selectivity picture depends on the voltage on your bus. At 220...240 V AC the Icu drops to 30 kA; at 380...415 V AC it's 15 kA; at 440 V AC it's 10 kA. Under the 60898-1 standard the Icn is 15 kA at 400 V AC. For a 400 V distribution panel, the 15 kA Icu at 415 V is what governs your upstream breaker coordination — that's the figure to plug into your selectivity study, not the 42 kA number.

Height is 91 mm, depth 78.5 mm. The double terminal accepts 1...25 mm² rigid or 1...16 mm² flexible wire; strip length 14 mm, tighten to 2 N.m. IP20 finger-safe front, pollution degree 3 rated, overvoltage category IV. That's a standard panel footprint — no surprises for a panel builder laying out a 4-pole MCB in a distribution board.

Frequently asked questions

What is the breaking capacity of A9F07413 at 400 V?

At 380...415 V AC the Icu is 15 kA per EN/IEC 60947-2; under EN/IEC 60898-1 the Icn is 15 kA at 400 V AC.

What is the closest alternative to A9F07413 in the Acti9 family?

Within the same Acti9 iC60H series, the closest peer would be a 4-pole C-curve MCB at a different current rating — the mechanical footprint, breaking capacity, and terminal specs are identical; only the thermal trip element changes. No pin-compatible alternative exists outside the iC60 family without re-verifying the DIN-rail layout and terminal capacity.

How do I get pricing and availability for A9F07413?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.

What compliance documentation does Schneider provide for A9F07413?

The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries IP20 per IEC 60529, and is tropicalised to class 2 per IEC 60068-1. Standard Schneider declarations of conformity and the product datasheet cover RoHS and REACH compliance — available on request with the RFQ.

MPN
A9F07413