Skip to main content
Schneider Electric A9F07450

Schneider Electric A9F07450 Acti9 iC60H MCB, 50 A C-Curve 4P

MPN A9F07450
Active

Schneider Electric Acti9 iC60H, A9F07450, miniature circuit breaker, 4P, 50 A, C-curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07450 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F07450 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07450 is an Acti9 iC60H miniature circuit breaker — a 4-pole, 50 A, C-curve device built for distribution boards and sub-distribution panels. It snaps onto a DIN rail, so panel integration is straightforward: 72 mm wide, 91 mm tall, 78.5 mm deep, occupying 8 x 9 mm pitches on the rail. The C-curve magnetic trip fires at 8 x In ±20 % — meaning it holds through moderate inrush (common with small motors, transformers, or lighting ballasts) and clears fast on a hard short. That 50 A rating on a 4-pole frame handles three-phase plus neutral, rated for distribution duty (Category A per EN/IEC 60947-2). Breaking capacity is the headline number here: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC (per IEC 60947-2). For IEC 60898-1 the Icn is 15 kA at 400 V AC, so the part is dual-rated and covers both standard families.

Strip length 14 mm, torque to 3.5 N·m. The toggle gives local switching, and the trip indicator shows a clear red/green flag when it's tripped — no guessing from across the panel. Earth-leakage protection is handled by a separate block (Vigi iC60), not integrated — so if you need RCD functionality, plan for the add-on module alongside this breaker on the rail.

MPN
A9F07450