A9F08140 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08140 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08140 is an Acti9 iC60H miniature circuit breaker — a 1-pole, 40 A thermal-magnetic MCB with a D tripping curve. It's built for distribution boards where high inrush loads (motors, transformers, welding equipment) need a breaker that holds through the start-up surge and clears fast on a hard fault. The D curve means magnetic tripping occurs at 12 x In (±20 %), so on a 40 A breaker the instantaneous trip threshold sits between 384 A and 576 A. That's deliberately higher than a B or C curve — it avoids nuisance trips from motor inrush or capacitive loads while still providing short-circuit protection.

Breaking capacity and dual-standard certification

Breaking capacity is rated under both IEC 60898-1 and IEC 60947-2, which is the dual-certification you want when the same breaker panel feeds both residential-style final circuits and industrial distribution. Under IEC 60898-1 (the MCB standard) it's 10 kA Icn at 230 V AC. Under IEC 60947-2 (the industrial standard) it's 15 kA Icu at 220–240 V AC, 30 kA at 100–133 V, and 42 kA at 12–60 V AC. On DC it delivers 20 kA at 12–60 V DC and 15 kA at 60–72 V DC. The 15 kA Icu at 230/240 V AC is the figure that matters for most European distribution panels.

Mounting, wiring, and panel fit

Snaps onto standard DIN rail. Width is 18 mm (2 x 9 mm pitches), so it occupies one modular space in a distribution board. Depth is 78.5 mm, height 91 mm — check your enclosure depth if you're retrofitting into a shallow gland plate. IP20 finger-safe protection on the front face.

MPN
A9F08140