Skip to main content
Schneider Electric A9F08304

Schneider Electric A9F08304 Acti9 iC60H MCB, 4A D Curve, 3P,

MPN A9F08304
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08304, 4 A, D curve, 3P, 70 kA Icu at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08304 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F08304 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08304 is an Acti9 iC60H miniature circuit breaker rated 4 A with a D tripping curve, three protected poles, and a 70 kA ultimate breaking capacity (Icu) at 415 V AC. It's a thermal-magnetic MCB built for distribution boards where high fault currents and inductive loads like small motors or transformers live.

The 78.5 mm depth leaves room in a shallow enclosure for the outgoing cables. Strip 14 mm and you're in business. It's rated for isolation — both EN/IEC 60898-1 and EN/IEC 60947-2 give it the thumbs-up for safe disconnect. The IP20 finger-safe terminals are standard for enclosed gear.

The iC60H carries a 70 kA Icu across the common low-voltage range — 12–133 V, 220–240 V, and 380–415 V AC. At 440 V it's still 50 kA. That's the H suffix: high breaking capacity for a 4 A frame. It's limitation class 3, so it lets through less fault energy downstream, which helps with cascading and selectivity coordination with downstream breakers. For IEC 60898-1 applications the Icn is 10 kA at 400 V. The 60947-2 Icu numbers are the real headroom — useful when you're tying this into an industrial panel with a big transformer upstream.

MPN
A9F08304