Schneider Electric A9F08304 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F08304 Acti9 iC60H MCB, 4A D Curve, 3P,

MPNA9F08304
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08304, 4 A, D curve, 3P, 70 kA Icu at 415 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08304 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08304 — Ratings
ParameterValue
Rated current (In)4 A
Poles configuration3P
Number of protected poles3
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08304 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08304 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08304 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08304 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08304 is an Acti9 iC60H miniature circuit breaker rated 4 A with a D tripping curve, three protected poles, and a 70 kA ultimate breaking capacity (Icu) at 415 V AC. It's a thermal-magnetic MCB built for distribution boards where high fault currents and inductive loads like small motors or transformers live.

The 78.5 mm depth leaves room in a shallow enclosure for the outgoing cables. Strip 14 mm and you're in business. It's rated for isolation — both EN/IEC 60898-1 and EN/IEC 60947-2 give it the thumbs-up for safe disconnect. The IP20 finger-safe terminals are standard for enclosed gear.

The iC60H carries a 70 kA Icu across the common low-voltage range — 12–133 V, 220–240 V, and 380–415 V AC. At 440 V it's still 50 kA. That's the H suffix: high breaking capacity for a 4 A frame. It's limitation class 3, so it lets through less fault energy downstream, which helps with cascading and selectivity coordination with downstream breakers. For IEC 60898-1 applications the Icn is 10 kA at 400 V. The 60947-2 Icu numbers are the real headroom — useful when you're tying this into an industrial panel with a big transformer upstream.

Frequently asked questions

What is the breaking capacity of A9F08304 at 415 V?

The A9F08304 carries a 70 kA Icu at 380–415 V AC 50/60 Hz per EN/IEC 60947-2. At 440 V it's 50 kA. The IEC 60898-1 Icn is 10 kA at 400 V.

What does the D curve mean on this MCB?

The D curve sets the magnetic trip threshold at 12 x In (±20%), so this 4 A breaker trips magnetically between roughly 38 A and 58 A. That's designed to ride through the inrush of motor loads, transformers, or discharge lamps without nuisance tripping.

Where can I buy A9F08304 and get current pricing?

We source and quote the A9F08304 to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution channels.

MPN