MPN A9F08316
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08316, 3P, 16 A, D curve, 42 kA breaking capacity, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08316 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F08316 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08316 is an Acti9 iC60H miniature circuit breaker — 3-pole, 16 A rated current, D-curve trip characteristic, with a 42 kA breaking capacity at 12–133 V AC. It is a thermal-magnetic MCB (Category A per EN/IEC 60947-2) suited for distribution applications where high inrush currents from motor or transformer loads demand a D-curve magnetic trip at 12 x In (±20 %).

At 220–240 V AC it still holds 30 kA Icu, and at 380–415 V AC it manages 15 kA Icu.

Occupies 6 x 9 mm pitches (54 mm wide) — three poles at 18 mm per pole. Height 91 mm, depth 78.5 mm. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; tightening torque 2 N·m. Wire strip length 14 mm. IP20 finger-safe front. Overvoltage category IV (mains entry level).

Rated insulation voltage 500 V AC. Electrical durability 10,000 cycles; mechanical durability 20,000 cycles. Earth-leakage protection requires a separate Vigi block — not integrated. Local trip indicator and contact position indicator standard. White colour, toggle control.