Specifications

A9F08316 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08316 — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08316 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08316 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08316 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08316 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08316 is an Acti9 iC60H miniature circuit breaker — 3-pole, 16 A rated current, D-curve trip characteristic, with a 42 kA breaking capacity at 12–133 V AC. It is a thermal-magnetic MCB (Category A per EN/IEC 60947-2) suited for distribution applications where high inrush currents from motor or transformer loads demand a D-curve magnetic trip at 12 x In (±20 %).

At 220–240 V AC it still holds 30 kA Icu, and at 380–415 V AC it manages 15 kA Icu.

Occupies 6 x 9 mm pitches (54 mm wide) — three poles at 18 mm per pole. Height 91 mm, depth 78.5 mm. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; tightening torque 2 N·m. Wire strip length 14 mm. IP20 finger-safe front. Overvoltage category IV (mains entry level).

Rated insulation voltage 500 V AC. Electrical durability 10,000 cycles; mechanical durability 20,000 cycles. Earth-leakage protection requires a separate Vigi block — not integrated. Local trip indicator and contact position indicator standard. White colour, toggle control.

Frequently asked questions

What is the breaking capacity of A9F08316?

42 kA Icu at 12–133 V AC, 30 kA Icu at 220–240 V AC, 15 kA Icu at 380–415 V AC, and 10 kA Icn at 400 V AC per EN/IEC 60898-1.

What curve and rated current does A9F08316 have?

D curve, 16 A rated current (In), with magnetic tripping at 12 x In ±20 %.