Skip to main content
Schneider Electric A9F43406

Schneider Electric A9F43406 Acti9 iC60N MCB, B-Curve 6A 4P,

MPN A9F43406
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F43406, 6 A, B-curve, 4P, 36 kA Icu at 133 V AC, clip-on rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F43406 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F43406 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F43406 is a 4-pole miniature circuit breaker from the Acti9 iC60N family, rated 6 A with a B-curve trip characteristic. The B-curve means the magnetic trip operates at 4 x In ±20 % — so between 19.2 A and 28.8 A — making it the standard choice for resistive or general-purpose loads where inrush is low. It is dual-rated to EN/IEC 60898-1 (for household/similar installations) and EN/IEC 60947-2 (for industrial applications), which gives it a 10 kA Icn at 415 V AC under the 60898 standard and a 36 kA Icu at 133 V AC under 60947-2. That 36 kA figure is the ultimate breaking capacity at the low-voltage end of its range — useful where fault current is high but the service voltage stays under 133 V AC. At 220–240 V AC the Icu drops to 20 kA, and at 380–415 V AC to 10 kA, so selectivity studies should use the voltage-specific rating, not the headline number.

The 4-pole body takes 8 x 9 mm pitches of rail space — 72 mm wide, 85 mm tall, 78.5 mm deep. IP20 finger-safe terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; strip length 14 mm, tighten to 2 N·m. The toggle actuator and trip indicator give local status without opening the door. Padlockable for lockout/tagout.

MPN
A9F43406