Schneider Electric A9F45403 iC60N MCB, D Curve 3 A 4P 50 kA

MPN A9F45403
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit-breaker A9F45403, 4P, D curve, 3 A rated, 50 kA breaking capacity at 415 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F45403 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F45403 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The A9F45403 is a Schneider Electric Acti9 iC60N miniature circuit breaker — 4 poles, D curve, 3 A rated current. At 3 A, this is sized for a small motor or control transformer branch, not a main feeder.

Dual-standard certification and lifecycle

Tightening torque 2 N·m. Strip length 14 mm. That covers most panel wiring up to a 4 mm² feed for a 3 A branch. The thermal-magnetic trip unit is non-interchangeable — no field-swap of the trip element, so order the exact rating. Padlockable toggle and a trip indicator (red flag visible when tripped) help the field tech confirm isolation before working downstream. Earth-leakage protection requires a separate vigi block — not integrated.