Skip to main content
Schneider Electric A9F45403 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F45403 iC60N MCB, D Curve 3 A 4P 50 kA

MPNA9F45403
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit-breaker A9F45403, 4P, D curve, 3 A rated, 50 kA breaking capacity at 415 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F45403 — Identification
ParameterValue
Product nameDisbo iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
A9F45403 — Ratings
ParameterValue
Rated current (In)3 A
Poles configuration4P
Number of protected poles4
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated operational voltage (Ue)12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
A9F45403 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F45403 — Mechanical
ParameterValue
Mounting supportRail
Mounting modeClip-on
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height85 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F45403 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F45403 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2

Product details

The A9F45403 is a Schneider Electric Acti9 iC60N miniature circuit breaker — 4 poles, D curve, 3 A rated current. At 3 A, this is sized for a small motor or control transformer branch, not a main feeder.

Dual-standard certification and lifecycle

Tightening torque 2 N·m. Strip length 14 mm. That covers most panel wiring up to a 4 mm² feed for a 3 A branch. The thermal-magnetic trip unit is non-interchangeable — no field-swap of the trip element, so order the exact rating. Padlockable toggle and a trip indicator (red flag visible when tripped) help the field tech confirm isolation before working downstream. Earth-leakage protection requires a separate vigi block — not integrated.

Frequently asked questions

Where can I buy A9F45403 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of A9F45403?

50 kA Icu at 415 V AC per EN/IEC 60947-2, and 6 kA Icn at 415 V AC per EN/IEC 60898-1. The 50 kA rating is the industrial interrupting capacity — it handles high fault currents without upstream fuses.

What is the D curve magnetic trip threshold?

12 x In ±20 %. For a 3 A breaker, that means magnetic trip between 28.8 A and 43.2 A. This holds motor inrush and transformer magnetizing current without nuisance tripping.

What compliance documentation does Schneider provide for A9F45403?

The part is certified to EN/IEC 60898-1 and EN/IEC 60947-2. It carries IP20 protection (IEC 60529), pollution degree 3, and tropicalisation class 2 (IEC 60068-1). RoHS and REACH declarations are standard for the Acti9 range.

MPN
A9F45403