Skip to main content
Schneider Electric A9F58106

Schneider Electric A9F58106 Acti9 IKQ MCB, D Curve 6 A, 10 k

MPN A9F58106
Obsolete

Schneider Electric Acti9 IKQ, miniature circuit breaker, 1P, 6 A, D curve, 10 kA Icn at 240 V AC, EN/IEC 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F58106 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage240 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to EN 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9F58106 additional specifications
ParameterValue
Pollution degree2 conforming to EN/IEC 60898-1
ColorWhite
Depth78.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9F58106 is a 1-pole Acti9 IKQ miniature circuit breaker rated 6 A with a D tripping curve, meaning the magnetic release operates at 10 to 14 times the rated current — sized for loads with high inrush such as small motors, transformers, or lighting ballasts where a B or C curve would nuisance-trip on startup. Its 10 kA Icn breaking capacity at 240 V AC (EN 60898-1) and 7.5 kA Ics service breaking capacity at the same voltage give it enough fault-interrupting headroom for most residential and light commercial distribution boards fed from a typical utility transformer. The thermal-magnetic trip unit provides overload protection via the bimetal element and short-circuit protection via the solenoid — no earth-leakage function integrated, so any residual-current protection must come from a separate RCCB or RCBO downstream.

Terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable at the bottom connection; tighten to 2 N·m with a strip length of 14 mm. The toggle actuator provides manual on/off control, and a trip indicator shows the breaker has operated on fault. Padlockable for lockout/tagout during maintenance.

Rated for 10,000 electrical and 20,000 mechanical cycles — suitable for frequent switching applications where the breaker also serves as a disconnect under load.

MPN
A9F58106