Skip to main content
Schneider Electric A9F68216

Schneider Electric A9F68216 Acti9 iT60 MCB, 16 A, C Curve, 1

MPN A9F68216
Active

Schneider Electric Acti9 iT60, A9F68216, miniature circuit breaker, 2P, 16 A rated current, C curve, 10 kA breaking capacity at 400 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68216 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width36 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F68216 is a 2-pole Acti9 iT60 miniature circuit breaker rated 16 A with a C curve — magnetic trip at 8 x In ±20 %, so it holds moderate inrush from motor starters or small transformers without nuisance tripping, while still clearing a hard short fast enough for downstream coordination. Breaking capacity is the headline: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, and 10 kA Icu at 380–415 V — plus 6 kA Icu at 440 V — all per EN/IEC 60947-2. For distribution duty under EN/IEC 60898-1 it carries 10 kA Icn at 400 V. That dual rating means it can serve either industrial feeder panels (60947-2) or commercial final circuits (60898-1) without swapping the part. Pollution degree 3 means it holds up in dirty or humid environments — the tropicalisation rating (2 conforming to EN/IEC 60068-2-78) backs that for 95 % RH. The removable comb busbar is already installed — wire up single terminals top or bottom, 1–25 mm² rigid or 1–16 mm² flexible, strip 14 mm, torque to 2 N·m.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / commercial). Suitability for isolation is confirmed under both standards. IP20 B finger protection on the front face.

MPN
A9F68216