Skip to main content
Schneider Electric A9F68216 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F68216 Acti9 iT60 MCB, 16 A, C Curve, 1

MPNA9F68216
Active

Schneider Electric Acti9 iT60, A9F68216, miniature circuit breaker, 2P, 16 A rated current, C curve, 10 kA breaking capacity at 400 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68216 — Identification
ParameterValue
Product nameActi9 iT60
Series / familyActi9
Device short nameiT60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F68216 — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
A9F68216 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
A9F68216 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Terminal connectionsSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F68216 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 %
A9F68216 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F68216 is a 2-pole Acti9 iT60 miniature circuit breaker rated 16 A with a C curve — magnetic trip at 8 x In ±20 %, so it holds moderate inrush from motor starters or small transformers without nuisance tripping, while still clearing a hard short fast enough for downstream coordination. Breaking capacity is the headline: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, and 10 kA Icu at 380–415 V — plus 6 kA Icu at 440 V — all per EN/IEC 60947-2. For distribution duty under EN/IEC 60898-1 it carries 10 kA Icn at 400 V. That dual rating means it can serve either industrial feeder panels (60947-2) or commercial final circuits (60898-1) without swapping the part. Pollution degree 3 means it holds up in dirty or humid environments — the tropicalisation rating (2 conforming to EN/IEC 60068-2-78) backs that for 95 % RH. The removable comb busbar is already installed — wire up single terminals top or bottom, 1–25 mm² rigid or 1–16 mm² flexible, strip 14 mm, torque to 2 N·m.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / commercial). Suitability for isolation is confirmed under both standards. IP20 B finger protection on the front face.

Frequently asked questions

What is the breaking capacity of A9F68216 at 400 V?

10 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

Where can I buy A9F68216 and get current pricing?

Sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What compliance standards does A9F68216 meet?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1, with suitability for isolation under both standards. Tropicalisation per EN/IEC 60068-2-78.

MPN
A9F68216