Skip to main content
Schneider Electric A9F68310

Schneider Electric A9F68310 Acti9 iT60 MCB, 10 A, C Curve, 3

MPN A9F68310
Active

Schneider Electric Acti9 iT60, A9F68310, miniature circuit breaker, 10 A, C curve, 3 poles, 54 mm width, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68310 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width54 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68310 is a 10 A, C-curve miniature circuit breaker from the Acti9 iT60 series, built for distribution boards where you need thermal-magnetic protection on a 3-pole AC/DC circuit. The 10 A rating sets the continuous current it carries without tripping; the C curve means magnetic trip occurs at 5 to 10 times rated current — 8 x In +/-20 % per the spec — so it handles moderate inrush from small motors or transformers without nuisance trips. Breaking capacity is the real differentiator here: 36 kA Icu at 133 V AC, 20 kA at 240 V, 10 kA at 415 V, and 6 kA at 440 V. That 10 kA at 415 V covers most European industrial panel fault levels; the 6 kA at 440 V is worth noting if your line runs 440 V three-phase — it's lower than the 415 V figure, so verify your prospective short-circuit current at that voltage.

The removable comb busbar is pre-installed, so you can daisy-chain phases across adjacent breakers without extra wiring. Terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible; strip length is 14 mm, torque to 2 N·m. IP20 finger-safe for enclosed panels.

MPN
A9F68310