Schneider Electric A9F68310 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F68310 Acti9 iT60 MCB, 10 A, C Curve, 3

MPNA9F68310
Active

Schneider Electric Acti9 iT60, A9F68310, miniature circuit breaker, 10 A, C curve, 3 poles, 54 mm width, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68310 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68310 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68310 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68310 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Number of 9 mm pitches6
A9F68310 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68310 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F68310 is a 10 A, C-curve miniature circuit breaker from the Acti9 iT60 series, built for distribution boards where you need thermal-magnetic protection on a 3-pole AC/DC circuit. The 10 A rating sets the continuous current it carries without tripping; the C curve means magnetic trip occurs at 5 to 10 times rated current — 8 x In +/-20 % per the spec — so it handles moderate inrush from small motors or transformers without nuisance trips. Breaking capacity is the real differentiator here: 36 kA Icu at 133 V AC, 20 kA at 240 V, 10 kA at 415 V, and 6 kA at 440 V. That 10 kA at 415 V covers most European industrial panel fault levels; the 6 kA at 440 V is worth noting if your line runs 440 V three-phase — it's lower than the 415 V figure, so verify your prospective short-circuit current at that voltage.

The removable comb busbar is pre-installed, so you can daisy-chain phases across adjacent breakers without extra wiring. Terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible; strip length is 14 mm, torque to 2 N·m. IP20 finger-safe for enclosed panels.

Frequently asked questions

What is the breaking capacity of the A9F68310 at 400 V?

At 400 V AC, the A9F68310 has a breaking capacity of 10 kA Icu per EN/IEC 60947-2 and 6 kA Icn per EN/IEC 60898-1. The 10 kA figure is the one to use for industrial panel design.

What does the C curve mean on this breaker?

The C curve means the magnetic trip operates at 5 to 10 times the rated current — specifically 8 x In +/-20 %. This suits circuits with moderate inrush, like small motors, transformers, or lighting banks, where a B curve would nuisance-trip but a D curve would delay too long for cable protection.

Where can I buy the A9F68310 and how is it quoted?

The A9F68310 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume or project needs.