Skip to main content
Schneider Electric A9F68316

Schneider Electric A9F68316 Acti9 iT60 MCB, 16 A, C Curve, 3

MPN A9F68316
Active

Schneider Electric Acti9 iT60, miniature circuit breaker, 16 A, C curve, 3P, 54 mm, DIN rail, thermal-magnetic, dual standard EN/IEC 60947-2 and 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68316 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width54 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F68316 is a 16 A, 3-pole miniature circuit breaker from Schneider Electric's Acti9 iT60 range, with a C curve (magnetic trip at 8 × In ±20 %). Breaking capacity is dual-rated: 10 kA Icn at 400 V AC per EN/IEC 60898-1 (the household-standard rating), and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2 (the industrial-standard rating).

At 54 mm wide (6 × 9 mm pitches), it occupies three modular spaces — the standard width for a 3-pole MCB. Removable comb busbar installed means it's ready for daisy-chaining line-side feeds across a row of breakers without extra wiring. Tropicalisation class 2 per EN/IEC 60068-2-78 means it withstands 95 % relative humidity — relevant for coastal or unconditioned plant rooms.

No official successor or direct cross-reference exists because it's the active model. If you're maintaining an older panel that used the previous-generation Multi9 or C60 range, the Acti9 iT60 is the direct functional replacement — same footprint, same curve, same breaking capacity class.

MPN
A9F68316