Skip to main content
Schneider Electric A9F68363

Schneider Electric A9F68363 Acti9 iT60 MCB, 63 A, C-Curve, 3

MPN A9F68363
Active

Schneider Electric Acti9 iT60N miniature circuit breaker, A9F68363, 3-pole, 63 A, C-curve, thermal-magnetic trip, 54 mm width, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68363 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width54 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

63 A C-curve MCB for distribution panels

The Schneider Electric A9F68363 is a 3-pole Acti9 iT60N miniature circuit breaker rated 63 A with a C-curve trip characteristic, designed for distribution applications in commercial and industrial panels.

This breaker carries dual certification to EN/IEC 60898-1 and EN/IEC 60947-2, giving two sets of breaking capacity figures. Under the industrial standard (60947-2), the ultimate breaking capacity Icu reaches 36 kA at 12–133 V AC, 20 kA at 220–240 V AC, 10 kA at 380–415 V AC, and 6 kA at 440 V AC. The limitation class is 3 per EN/IEC 60898-1, meaning it restricts let-through energy enough to protect downstream equipment in most fault scenarios. The 6 kA Icu at 440 V AC is the weakest link in the curve — if your panel feeds a 440 V bus with available fault current above that, you need a higher-rated upstream breaker or a current-limiting fuse ahead of this device. At 400 V, the 10 kA Icn aligns with typical commercial panel specs.

Terminals accept 1–35 mm² rigid or 1–25 mm² flexible copper; strip length is 14 mm. The IP20 B finger-safe enclosure (IEC 60529) covers the terminals, but the busbar area remains exposed — plan for a dead-front cover or shrouded busbar in the panel layout. Operating temperature range is -35 to 70 °C, storage -40 to 85 °C, with 95 % relative humidity tolerance and tropicalisation level 2 per IEC 60068-2-78. Suitable for non-condensing environments in most indoor industrial settings.

MPN
A9F68363