Specifications

A9F68363 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68363 — Ratings
ParameterValue
Rated current (In)63 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68363 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68363 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Number of 9 mm pitches6
A9F68363 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68363 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

63 A C-curve MCB for distribution panels

The Schneider Electric A9F68363 is a 3-pole Acti9 iT60N miniature circuit breaker rated 63 A with a C-curve trip characteristic, designed for distribution applications in commercial and industrial panels.

This breaker carries dual certification to EN/IEC 60898-1 and EN/IEC 60947-2, giving two sets of breaking capacity figures. Under the industrial standard (60947-2), the ultimate breaking capacity Icu reaches 36 kA at 12–133 V AC, 20 kA at 220–240 V AC, 10 kA at 380–415 V AC, and 6 kA at 440 V AC. The limitation class is 3 per EN/IEC 60898-1, meaning it restricts let-through energy enough to protect downstream equipment in most fault scenarios. The 6 kA Icu at 440 V AC is the weakest link in the curve — if your panel feeds a 440 V bus with available fault current above that, you need a higher-rated upstream breaker or a current-limiting fuse ahead of this device. At 400 V, the 10 kA Icn aligns with typical commercial panel specs.

Terminals accept 1–35 mm² rigid or 1–25 mm² flexible copper; strip length is 14 mm. The IP20 B finger-safe enclosure (IEC 60529) covers the terminals, but the busbar area remains exposed — plan for a dead-front cover or shrouded busbar in the panel layout. Operating temperature range is -35 to 70 °C, storage -40 to 85 °C, with 95 % relative humidity tolerance and tropicalisation level 2 per IEC 60068-2-78. Suitable for non-condensing environments in most indoor industrial settings.

Frequently asked questions

What is the A9F68363's rated current and breaking capacity?

Rated current is 63 A. Breaking capacity varies by voltage: 36 kA Icu at 133 V AC, 20 kA at 240 V, 10 kA at 415 V, 6 kA at 440 V (per IEC 60947-2), and 10 kA Icn at 400 V (per IEC 60898-1).

What standards does the A9F68363 comply with?

It is certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household) standards, with suitability for isolation confirmed under both. Pollution degree 3, overvoltage category IV.

Where can I buy the A9F68363 and how is it quoted?

The A9F68363 is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm offer.

MPN
A9F68363