Skip to main content
Schneider Electric A9F68450

Schneider Electric A9F68450 Acti9 iT60 MCB, 50 A, C-Curve, 4

MPN A9F68450
Active

Schneider Electric Acti9 iT60 miniature circuit breaker, 50 A, C-curve, 4 poles, 72 mm wide, breaking capacity 36 kA at 240 V AC, DIN-rail mount, current production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68450 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width72 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68450 is a 4-pole Acti9 iT60 miniature circuit breaker rated 50 A with a C-curve, built for distribution panels where you need a thermal-magnetic trip that handles moderate inrush without nuisance tripping. It's dual-rated to EN/IEC 60947-2 and EN/IEC 60898-1, so the same breaker qualifies for industrial panel (60947-2) and final-distribution (60898-1) duty; the 60947-2 rating gives you the higher short-circuit capacity numbers that matter when you're coordinating with upstream gear in a mine or mill switchroom. The breaking capacity tells the real story: 36 kA Icu at 240 V AC, 20 kA at 240 V, 10 kA at 415 V, and 6 kA at 440 V — all per IEC 60947-2. The 10 kA Icn at 400 V per IEC 60898-1 is the commercial-distribution rating; the 60947-2 numbers are what the panel designer uses for the SCCR declaration on the nameplate.

The removable comb busbar is already accounted for in the mounting mode — you can bus the line side across multiple breakers without extra hardware. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible on a single terminal top or bottom; strip length 14 mm, torque to 3.5 N·m. IP20 B finger-safe terminals keep the panel builder safe during commissioning.

MPN