Skip to main content
Schneider Electric A9FDB606

Schneider Electric A9FDB606 Acti9 iDPN N Arc, 6A C-curve AFD

MPN A9FDB606
Obsolete

Schneider Electric Acti9 iDPN N Arc, arc fault detection circuit breaker (AFDD), 1P+N, 6 A rated current, C-curve, 6 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9FDB606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz conforming to IEC 62606 230 V AC 50 Hz conforming to EN/IEC 60898-1
Insulation voltage ui400 V AC
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9FDB606 additional specifications
ParameterValue
Pollution degree2
ColorWhite
Depth72 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

Arc fault detection circuit breaker, 6 A C-curve, 1P+N

The Schneider Electric A9FDB606 is an Acti9 iDPN N Arc arc fault detection circuit breaker (AFDD) combining overcurrent protection with series arc-fault detection in a single 1P+N module. Rated 6 A at 30 °C with a C-curve magnetic trip (5...10 x In), it breaks 6000 A Icn at 230 V AC 50 Hz per EN/IEC 60898-1. The thermal-magnetic trip unit covers overload and short-circuit; the arc-fault electronics detect hazardous series arcing downstream and trip the circuit independently of the overcurrent mechanism.

The 6 kA breaking capacity at 230 V AC is the maximum fault current it can safely interrupt; this matches typical domestic and light commercial panel fault levels (IEC 60898-1). Limitation class 3 means it restricts let-through energy under short-circuit, reducing stress on downstream wiring and devices.

Clip-on mounting to DIN rail, 36 mm wide (2 modular spaces), 81 mm tall, 72 mm deep. Neutral on the left, phase on the right — tunnel terminals accept up to 16 mm² rigid or 10 mm² flexible (single cable), or 2.5 mm² for two cables. Tightening torque 2 N·m, strip length 14 mm. The 9 mm pitch between phase and neutral terminals matches standard Acti9 busbar spacing.

MPN
A9FDB606