Skip to main content
Schneider Electric A9FDB610

Schneider Electric A9FDB610 Acti9 iDPN N Arc, 10A C-Curve AF

MPN A9FDB610
Obsolete

Schneider Electric Acti9 iDPN N Arc, arc fault detection circuit breaker, 1P+N, 10 A, C curve, 6 kA Icn at 230 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9FDB610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz conforming to IEC 62606 230 V AC 50 Hz conforming to EN/IEC 60898-1
Insulation voltage ui400 V AC
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9FDB610 additional specifications
ParameterValue
Pollution degree2
ColorWhite
Depth72 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

Arc fault detection circuit breaker, 1P+N, 10 A, C curve

The Schneider Electric A9FDB610 is an Acti9 iDPN N Arc arc fault detection circuit breaker (AFDD) — a single-module (36 mm wide) 1P+N device that combines overcurrent protection with series arc fault detection per IEC 62606. Rated 10 A at 30 °C with a C curve (magnetic trip 5...10 x In), it breaks 6000 A Icn at 230 V AC 50 Hz (IEC 60898-1). The thermal-magnetic trip unit handles both overload and short-circuit; the arc-fault electronics monitor the downstream circuit for dangerous series arcs and trip the breaker when detected.

The 1P+N format (switched phase, switched neutral) isolates both poles on a fault, which is required in some national wiring regs. Limitation class 3 (IEC 60898-1) means it lets through less energy during a short-circuit, helping downstream selectivity.

The 9 mm pitch between phase and neutral terminals matches the Acti9 busbar system. Tunnel-type terminals accept up to 16 mm² rigid or 10 mm² flexible (single cable), or 2 × 2.5 mm². IP20 finger-safe terminals. The toggle switch gives ON/OFF/trip indication.

The A9FDB610 is listed as current production (active lifecycle). The Acti9 range is widely specified, so cross-referencing to a panel BOM is straightforward.

MPN
A9FDB610