Skip to main content
Schneider Electric A9K14120

Schneider Electric A9K14120 Acti9 iK60N MCB, 20 A, 1P, C-Cur

MPN A9K14120
Obsolete

Schneider Electric Acti9 iK60N, miniature circuit-breaker, A9K14120, 1P, 20 A, C-curve, 4500 A Icn at 230 V AC, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K14120 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K14120 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K14120 is a 1-pole miniature circuit breaker from the Acti9 iK60N range, rated 20 A at 30 °C with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). It clips onto a standard DIN rail — two 9 mm pitches wide, so it takes up 18 mm of panel space. The breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, certified to EN/IEC 60898-1.

The C-curve means the magnetic trip fires between 5 and 10 times the rated current — so for this 20 A breaker, instantaneous trip happens between 100 A and 200 A. If you were protecting a motor or a transformer with a higher starting surge, you'd typically reach for a D-curve instead. The thermal-magnetic trip unit handles the overload side (the thermal bimetal) and the short-circuit side (the magnetic coil) in one compact package. Rated insulation voltage is 440 V AC, and the overvoltage category is III, which covers fixed installations inside a building distribution board. The part is rated for isolation — it has a positive ON/OFF indication on the toggle, so you can visibly confirm the circuit is open before working downstream.

Termination and wiring notes

Strip length is 14 mm.

MPN
A9K14120