Skip to main content
Schneider Electric A9K14120 — 1-Pole MCB (DIN Rail)

Schneider Electric A9K14120 Acti9 iK60N MCB, 20 A, 1P, C-Cur

MPNA9K14120
Obsolete

Schneider Electric Acti9 iK60N, miniature circuit-breaker, A9K14120, 1P, 20 A, C-curve, 4500 A Icn at 230 V AC, DIN-rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9K14120 — Identification
ParameterValue
Product nameActi9 iK60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiK60N
Poles description1P
Number of protected poles1
Device applicationDistribution
A9K14120 — Electrical & Protection
ParameterValue
Rated current (In)20 A at 30 °C
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9K14120 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (top or bottom) 1...25 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom
A9K14120 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9K14120 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9K14120 — Electrical
ParameterValue
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60898-1

Product details

The Schneider Electric A9K14120 is a 1-pole miniature circuit breaker from the Acti9 iK60N range, rated 20 A at 30 °C with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). It clips onto a standard DIN rail — two 9 mm pitches wide, so it takes up 18 mm of panel space. The breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, certified to EN/IEC 60898-1.

The C-curve means the magnetic trip fires between 5 and 10 times the rated current — so for this 20 A breaker, instantaneous trip happens between 100 A and 200 A. If you were protecting a motor or a transformer with a higher starting surge, you'd typically reach for a D-curve instead. The thermal-magnetic trip unit handles the overload side (the thermal bimetal) and the short-circuit side (the magnetic coil) in one compact package. Rated insulation voltage is 440 V AC, and the overvoltage category is III, which covers fixed installations inside a building distribution board. The part is rated for isolation — it has a positive ON/OFF indication on the toggle, so you can visibly confirm the circuit is open before working downstream.

Termination and wiring notes

Strip length is 14 mm.

Frequently asked questions

What is the breaking capacity of A9K14120?

4500 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. That's the maximum prospective fault current it can safely interrupt at that voltage.

What is the depth of A9K14120?

78.5 mm. That's the body depth from the front of the DIN rail to the back of the toggle — standard for a single-module Acti9 iK60N MCB.

MPN