Skip to main content
Schneider Electric A9K24204

Schneider Electric A9K24204 Acti9 iK60N MCB, C-Curve 4A 2P 6

MPN A9K24204
Active

Schneider Electric Acti9 iK60N, A9K24204, miniature circuit breaker, 2P, 4 A, C-curve, 6 kA Icn at 400 V AC, thermal-magnetic, DIN rail mount.

$17.13 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24204 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24204 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K24204 is a 2-pole miniature circuit breaker from the Acti9 iK60N series, rated 4 A with a C-curve trip characteristic. It is a thermal-magnetic MCB designed for distribution in residential and commercial final circuits, built and certified to EN/IEC 60898-1. The C-curve (magnetic tripping limit 5 to 10 x In) means it is sized for inductive loads like small motors, fluorescent lighting, and transformers where inrush current is moderate — not for pure resistive loads (B-curve) or heavy motor starts (D-curve). The 4 A rating at 30 °C ambient covers low-current sub-circuits such as lighting groups or control transformers. Breaking capacity is 6000 A Icn at 400 V AC, which is the standard domestic/commercial fault level for this class. The 2-pole version switches both phase and neutral, with both poles protected.

Clip-on mounting to DIN rail, 36 mm width (4 module pitches of 9 mm). Occupies two standard DIN-rail positions in the distribution board. Toggle actuator with ON/OFF visual indication; padlocking device available for lockout/tagout. Tightening torque 2 N·m, strip length 14 mm.

MPN
A9K24204