Schneider Electric A9K24625

A9K24625 Acti9 iK60N MCB, 25 A, C-Curve, 1P+N, 6 kA

MPN A9K24625
Obsolete

Schneider Electric Acti9 iK60N, A9K24625, miniature circuit breaker, 1P+N, 25 A, C-curve, 6 kA Icn at 230 V AC, thermal-magnetic, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24625 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Acti9 iK60N — 25 A C-Curve MCB for Distribution Boards

The Schneider Electric A9K24625 is a miniature circuit breaker from the Acti9 iK60N series, designed for AC distribution networks at 50/60 Hz. It is a single-pole-plus-neutral (1P+N) device rated 25 A at 30 °C with a C-curve trip characteristic (magnetic tripping limit 5...10 x In), making it suitable for protecting general-purpose circuits with moderate inrush currents — typical for lighting, socket outlets, and small motor loads in commercial and residential panels. Rated breaking capacity is 6000 A Icn at 230 V AC, conforming to EN/IEC 60898-1. The trip unit is thermal-magnetic: the thermal bimetal protects against sustained overloads, while the solenoid coil provides instantaneous magnetic protection on short-circuits.

This 1P+N form factor saves one module width compared to a 2-pole breaker, which matters when filling a distribution board with multiple circuits. Dimensions are 85 mm height and 78.5 mm depth, fitting standard enclosure depths. The neutral is on the left side of the unit; the tunnel-type terminals accept 1...25 mm² rigid or 1...16 mm² flexible cable, with a tightening torque of 2 N.m and a strip length of 14 mm. IP20 rated for finger-safe installation inside an enclosed panel.

Rated insulation voltage (Ui) is 440 V AC. Overvoltage category II and pollution degree 2 are standard for fixed-installation distribution boards. The toggle provides local ON/OFF indication; a padlocking device can be fitted for lockout/tagout procedures.

MPN
A9K24625