Schneider Electric A9K24663 Acti9 iK60N MCB, C-Curve 63 A, 6

MPN A9K24663
Active

Schneider Electric Acti9 iK60N, A9K24663, miniature circuit breaker, 1P+N, 63 A, C-curve, 6 kA Icn at 230 V AC, thermal-magnetic trip, DIN rail clip-on, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24663 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24663 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

This is a 1P+N (single-pole protected, switched neutral) configuration — the phase pole has the thermal-magnetic trip, and the neutral pole switches but doesn't protect. The neutral sits on the left side of the unit. That matters when you're wiring a single-phase final subcircuit where you need to isolate both conductors but only protect the line. That's a compact footprint for a 63 A 1P+N unit; you can fit about 8 of these per foot of DIN rail in a distribution board. The tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible, with a recommended tightening torque of 3.5 N.m and a strip length of 14 mm. Terminal capacity that generous for the 63 A rating means you can land larger incoming cables without needing an adapter or reducing the conductor.

It's certified to EN/IEC 60898-1, which is the harmonized European standard for MCBs used in household and similar installations. The limitation class 3 rating means it limits the let-through energy (I²t) to a level that protects downstream equipment better than a class 1 or 2 device — useful when you're coordinating with sensitive loads or trying to achieve selectivity with an upstream breaker.

Where it's used and how it fits

This MCB goes into a DIN-rail enclosure — typically a consumer unit, distribution board, or sub-distribution panel in a commercial building, small workshop, or residential installation. It's a distribution device (per the application field), meaning it's the downstream protection for lighting, socket circuits, and small loads, not the main incoming breaker. Rated insulation voltage is 440 V AC, so it's fine on a 230/400 V three-phase system when used on a single-phase leg. The IP20 protection means it's touch-safe but not splash-proof — install it inside a panel, not out in the weather.

MPN