Schneider Electric A9N16252

Schneider Electric A9N16252 Acti9 xID RCCB, 4P 25 A 300 mA A

MPN A9N16252
Active

Schneider Electric Acti9 xID, A9N16252, 4P RCCB, 25 A, 300 mA Type AC, 400…415 V AC, 50 Hz, IEC 61008.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N16252 specifications
ParameterValue
Control typeToggle
Voltage400...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth75 mm
Width72 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles4000 cycles
Operating temperature-5...40 °C

Product details

The Schneider Electric A9N16252 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated 25 A with a 300 mA Type AC earth-leakage sensitivity. It operates on a 400…415 V AC 50 Hz network and clips onto a DIN rail for panel integration. The instantaneous trip response (no intentional delay) means it clears ground faults as they happen — no coordination window for nuisance tripping on inrush, but also no selectivity with downstream RCCDs of the same type.

The 25 A rated current (In) and 300 mA sensitivity define the load and protection boundary. For a 4-pole RCCB on a 400 V three-phase system, 25 A covers typical sub-distribution or lighting circuits — not a main incoming breaker. The Type AC classification means it detects sinusoidal AC earth-leakage only; pulsed DC or smooth DC faults (from VFDs, UPS, or rectified loads) will pass through undetected. If the downstream load includes any power electronics, you need a Type A or Type B RCCB instead. Breaking capacity is 500 A per IEC 61008-1. In a panel with an upstream MCB, the RCCB relies on the MCB to clear high faults. Insulation voltage (Ui) is 500 V AC, and operational voltage (Ue) is 400…415 V AC. The 50 Hz network frequency is fixed.

The 4-pole body occupies 8 modules of 9 mm pitch (72 mm total width). Neutral is on the left. Tunnel terminals accept 1…35 mm² rigid or 1…25 mm² flexible — strip 14 mm, torque to 3.5 N·m. The 18 mm phase-to-phase pitch matches standard busbar systems in Acti9 distribution boards. IP20 finger-safe terminals are fine inside an enclosed panel. The white body with toggle control and local signalling (ON, OFF, fault trip) gives clear visual status. A padlocking device is available for lockout/tagout.