Schneider Electric A9N17518

Schneider Electric A9N17518 iDPN N MCB, 13 A, 1P+N, Curve B,

MPN A9N17518
Obsolete

Schneider Electric Clario iDPN N miniature circuit breaker, A9N17518, 13 A, 1P+N, Curve B, 6 kA Icn at 230 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N17518 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N17518 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-1
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It protects a single pole (phase) and switches the neutral, all in an 18 mm wide, clip-on DIN rail footprint. The thermal-magnetic trip unit gives you the standard two-stage protection: thermal overload on sustained overcurrent, magnetic instant trip on short-circuit. It's a workhorse MCB, not a specialty device — the sort you'd reach for when the BOM calls for a 13 A single-pole breaker and you need it to fit a standard DIN-rail enclosure.

For a panel with multiple breakers ganged together, you'll want to derate per the manufacturer's thermal table — standard practice in a crowded enclosure. That's fast enough to clear a hard short before the downstream wiring takes damage, but it won't nuisance-trip on the small inrush of a few LED drivers or a contactor coil. If your load has a motor start or transformer inrush, you'd want a Curve C or D — this one's for the predictable, low-surge branch. For most final sub-circuits in a TN or TT system, 6 kA is the standard floor. The 1P+N configuration switches the phase and disconnects the neutral, but the neutral pole is not protected — it's a switched neutral, not a second protected pole. That's typical for single-phase final circuits where the neutral is bonded at the source. The neutral sits on the left side of the breaker, which matters for busbar alignment in a split-bus panel.

That's one module wide — tight for a 1P+N in some older ranges, but standard for the iDPN N family. The 78 mm depth leaves room in a shallow enclosure; you're not fighting gland-plate clearance. Tunnel-type terminals accept 0.75 to 16 mm² rigid or 0.33 to 10 mm² flexible upstream and downstream. IP20 finger protection on the front — standard for a panel-mounted device.

Operating altitude rated to 2000 m without derating. Above that, the air's lower dielectric strength reduces the breaker's interrupting capacity — standard practice to derate 1% per 100 m above 2000 m if you're installing at altitude. Electrical and mechanical durability both rated at 20,000 cycles. That's the standard endurance for an MCB in distribution duty — not a frequent-switching device like a contactor, but fine for the occasional manual isolation or fault clearance it will see in its service life.

MPN
A9N17518