Schneider Electric A9N17520

Schneider Electric A9N17520 iDPN N MCB, 20 A, Curve B, 6 kA

MPN A9N17520
Obsolete

Schneider Electric Clario iDPN N miniature circuit breaker, A9N17520, 1P+N, 20 A, curve B, 6 kA breaking capacity at 230 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N17520 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N17520 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-1
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The B curve means magnetic tripping occurs at 3 to 5 times the rated current (60 to 100 A) — designed for resistive or lighting loads with low inrush, not motor starting. The 6 kA breaking capacity at 230 V AC (Icn per EN/IEC 60898-1) tells you it can safely interrupt a fault current up to 6,000 A without welding contacts or cascading failure upstream. That is the standard domestic and light commercial fault level; for higher prospective short-circuit currents you would step to a 10 kA or 15 kA rated breaker. The thermal-magnetic trip unit combines a bimetal strip for overload protection (slow response to sustained overcurrent) with a solenoid for short-circuit protection (instantaneous on high fault). This is the standard dual-action mechanism for MCBs; no electronic adjustment here — you select the rating and curve, and it is fixed. The 1P+N configuration switches the line conductor only; the neutral is switched but not protected. The neutral pole opens and closes with the line pole, providing isolation on both conductors when the toggle is off.

The 18 mm width per pole (2 x 9 mm pitches) means this 1P+N unit occupies two modules — 18 mm total. Plan your DIN rail fill accordingly; a standard 12-module enclosure holds six of these breakers side by side. Tunnel-type terminals accept 0.75 to 16 mm² rigid or 0.33 to 10 mm² flexible cable. The neutral terminal is on the left side of the unit.