Skip to main content
Schneider Electric A9N19663

Schneider Electric A9N19663 DPN N Vigi RCBO, 10A C-Curve 30m

MPN A9N19663
Active

Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, 10 A, C-curve, 30 mA earth leakage, 1P+N, 6 kA Icn at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19663 specifications
ParameterValue
Control typeToggle
Product typeType AC
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N19663 is an Acti9 DPN N Vigi residual current circuit breaker with overcurrent protection (RCBO), combining a 10 A C-curve thermal-magnetic trip with integrated 30 mA Type AC earth-leakage detection in a single 1P+N module. It's a current-production part, so no lifecycle hunting — this is the active catalog number for a distribution-board outgoing circuit needing both overcurrent and earth-fault protection in one DIN-rail slot.

For industrial panels with higher fault levels, step up to a 10 kA or 15 kA rated device. Rated 10 A at 30 °C ambient, this RCBO handles a continuous load of about 2.3 kW on a 230 V single-phase circuit. The thermal-magnetic trip unit is voltage-independent for the overcurrent element, while the residual current detection is also voltage-independent per the spec — meaning it maintains earth-leakage protection even if the neutral is lost upstream.

Neutral is on the left, phase on the right — wire it in that order to keep the internal neutral disconnect aligned. The 2000 m operating altitude covers most sites without derating.

It carries full EN/IEC 61009-1 and 61009-2-1 certification, which is the harmonized standard for RCBOs in the EU.

Rated for 20,000 electrical and 20,000 mechanical cycles — that's the endurance for a distribution board that sees regular switching, not a daily-use switch. The ON/OFF indicator and contact position indicator give a visual confirmation of state without needing to meter the load side.

MPN