Skip to main content
Schneider Electric A9N19663 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19663 DPN N Vigi RCBO, 10A C-Curve 30m

MPNA9N19663
Active

Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, 10 A, C-curve, 30 mA earth leakage, 1P+N, 6 kA Icn at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19663 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19663 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19663 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19663 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19663 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19663 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Schneider Electric A9N19663 is an Acti9 DPN N Vigi residual current circuit breaker with overcurrent protection (RCBO), combining a 10 A C-curve thermal-magnetic trip with integrated 30 mA Type AC earth-leakage detection in a single 1P+N module. It's a current-production part, so no lifecycle hunting — this is the active catalog number for a distribution-board outgoing circuit needing both overcurrent and earth-fault protection in one DIN-rail slot.

For industrial panels with higher fault levels, step up to a 10 kA or 15 kA rated device. Rated 10 A at 30 °C ambient, this RCBO handles a continuous load of about 2.3 kW on a 230 V single-phase circuit. The thermal-magnetic trip unit is voltage-independent for the overcurrent element, while the residual current detection is also voltage-independent per the spec — meaning it maintains earth-leakage protection even if the neutral is lost upstream.

Neutral is on the left, phase on the right — wire it in that order to keep the internal neutral disconnect aligned. The 2000 m operating altitude covers most sites without derating.

It carries full EN/IEC 61009-1 and 61009-2-1 certification, which is the harmonized standard for RCBOs in the EU.

Rated for 20,000 electrical and 20,000 mechanical cycles — that's the endurance for a distribution board that sees regular switching, not a daily-use switch. The ON/OFF indicator and contact position indicator give a visual confirmation of state without needing to meter the load side.

Frequently asked questions

What is the A9N19663's earth leakage sensitivity and type?

30 mA, Type AC — sinusoidal AC residual currents only. Standard for socket-outlet and general lighting circuits; not suitable for loads with rectified or pulsed DC fault currents.

Where can I buy the A9N19663?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this RCBO?

6 kA Icn at 230 V AC per EN 61009, which covers the prospective short-circuit current at most domestic and light commercial distribution boards in IEC markets.

MPN
A9N19663