Skip to main content
Schneider Electric A9N19755

Schneider Electric A9N19755 Acti9 DPN Vigi RCBO, 13 A, 30 mA

MPN A9N19755
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, 1P+N, 13 A, B curve, 30 mA earth leakage, 6 kA breaking capacity, 36 mm wide, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19755 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19755 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N19755 is an Acti9 DPN Vigi residual-current circuit breaker with overcurrent protection (RCBO), combining a 13 A thermal-magnetic trip (B curve) and 30 mA earth-leakage protection in a single 36 mm wide, 1P+N module.

The 13 A rated current (In) with B-curve magnetic trip (3–5 × In) means this RCBO is sized for residential or light commercial lighting and socket circuits where inrush is moderate — a B curve clears fast on short-circuit but avoids nuisance trips on small motor or capacitive loads. The 30 mA earth-leakage sensitivity provides personnel protection against direct contact, meeting the standard for socket-outlet circuits in most IEC 60364 installations. Breaking capacity is 6000 A Icn at 220–240 V AC, 50/60 Hz, which covers the typical prospective short-circuit current at the distribution board in most residential and small commercial panels.

Tunnel terminals accept 0.75–16 mm² rigid or 0.33–10 mm² flexible conductors, with a stripping length of 15 mm and tightening torque of 2 N·m. IP20 rated on the body, IP40 in a modular enclosure — suitable for dry indoor distribution boards.

MPN
A9N19755