Skip to main content
Schneider Electric A9N19755 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19755 Acti9 DPN Vigi RCBO, 13 A, 30 mA

MPNA9N19755
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, 1P+N, 13 A, B curve, 30 mA earth leakage, 6 kA breaking capacity, 36 mm wide, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19755 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9N19755 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9N19755 — Identification
ParameterValue
Product nameActi9 DPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameDPN N Vigi
A9N19755 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 0.75...16 mm² rigid Tunnel type terminal top or bottom 0.33...10 mm² flexible Tunnel type terminal top or bottom 0.33...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height81 mm
Depth77.5 mm
A9N19755 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-30...70 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity90 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N19755 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9N19755 is an Acti9 DPN Vigi residual-current circuit breaker with overcurrent protection (RCBO), combining a 13 A thermal-magnetic trip (B curve) and 30 mA earth-leakage protection in a single 36 mm wide, 1P+N module.

The 13 A rated current (In) with B-curve magnetic trip (3–5 × In) means this RCBO is sized for residential or light commercial lighting and socket circuits where inrush is moderate — a B curve clears fast on short-circuit but avoids nuisance trips on small motor or capacitive loads. The 30 mA earth-leakage sensitivity provides personnel protection against direct contact, meeting the standard for socket-outlet circuits in most IEC 60364 installations. Breaking capacity is 6000 A Icn at 220–240 V AC, 50/60 Hz, which covers the typical prospective short-circuit current at the distribution board in most residential and small commercial panels.

Tunnel terminals accept 0.75–16 mm² rigid or 0.33–10 mm² flexible conductors, with a stripping length of 15 mm and tightening torque of 2 N·m. IP20 rated on the body, IP40 in a modular enclosure — suitable for dry indoor distribution boards.

Frequently asked questions

What is the breaking capacity of the A9N19755?

The A9N19755 has a breaking capacity of 6000 A Icn at 220–240 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

What is the earth-leakage sensitivity of this RCBO?

The integrated earth-leakage protection is set at 30 mA sensitivity, providing personnel protection for socket-outlet circuits.

How do I get current pricing and availability for the A9N19755?

Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; we source through independent distribution and provide a firm quote with lead time.

What compliance documentation does Schneider provide for the A9N19755?

The A9N19755 is certified to EN/IEC 61009-2-1, with pollution degree 3 and overvoltage category III per IEC 60364. Tropicalisation class 2 per IEC 60068-1 is also listed. Specific RoHS/REACH declarations are available on request.

MPN